RTC-R
|
| Ranges |
Accuracy |
Stability |
| -45*
+155°C |
±0.04°C**; ±0.10°C |
±0.005°C |
| -30*
+155°C |
±0.04°C**; ±0.10°C |
±0.005°C |
| +33
+700°C |
±0.11°C**; ±0.29°C |
±0.008
0.02°C |
* at 20°C ambient
** with external reference sensor
Input signal measurement
| Input |
Accuracy |
| Thermocouples (GOST, IEC, DIN) |
±(0.005% RDG+0.005%FS) mV |
| RTDs (GOST, IEC, DIN) |
±0.026°C (0°C); ±0.03°C (155°C); ±0.049°C (700°C) |
| External Pt100 reference sensor |
±0.008°C (0°C); ±0.011°C (155°C); ±0.02°C (700°C) |
| DLC sensor |
±0.014°C (-50°C); ±0.01°C (0
155°C); ±0.01°C (700°C) |
| Current (4
20 mA) |
±(0.005% RDG+0.01%FS) |
| Voltage (0
12 V) |
±(0.005% RDG+0.01%FS) |
|
ATC-R
|
| Ranges |
Accuracy |
| -90*
+125°C |
±0.06°C**; ±0.3°C |
| -48*
+155°C |
±0.04°C**; ±0.13°C |
| -23*
+140°C |
±0.04°C**; ±0.18°C |
| +28
+250°C |
±0.07°C**; ±0.28°C |
| +33
+320°C |
±0.07°C**; ±0.2°C |
| +33
+650°C |
±0.11°C**; ±0.3°C |
| when used as a liquid bath: |
| -21*
+140°C |
±0.04°C**; ±0.3°C |
| +28
+250°C |
±0.07°C**; ±0.5°C |
|
* at 20°C ambient
**with external reference sensor
|
Input signal measurement
| Input |
Accuracy |
| Thermocouples (GOST, IEC, DIN) |
±(0.01% RDG+0.005%FS)°C |
| RTDs |
±0.058°C (0°C); ±0.106°C (650°C) |
| External Pt100 reference sensor |
±0.023°C (0°C); ±0.047°C (500°C) |
| Current (4
20 mA) |
±(0.015% RDG+0.01%FS) |
| Voltage (0
12 V) |
±(0.005% RDG+0.01%FS) |
|
|
CTC
 |
|
| Ranges |
Accuracy |
| -20*
+140°C |
±0.4°C |
| +33
+320°C |
±0.5°C |
| +33
+650°C |
±0.6/±0.9°C |
| +300
+1205°C |
±2,0°C |
|
*-20°C at 20°C ambient
|
|
ETC
 |
|
| Ranges |
Accuracy |
| -10*
+140°C |
±0.5°C |
| +28
+400°C |
±0.5°C |
|
*-10°C at 23°C ambient
|
|
DTI-1000 Precision Digital Thermometer
 |
|
| Range |
-200
+750°C |
| Accuracy |
±0.03°C (up to 400°C); ±0.06°C (up to 650°C)
|
| Sensor |
Pt100, 4 mm diameter, linear (250, 350 or 500 mm long) or 90° angled (165 mm long) |
|
|
ASM-R advanced signal multi-scanner
 |
|
| Number of channels |
8, 16 or 24 |
| Scan rate |
up to 5 channels per second |
Temperature sensor under test: signal measurement
| Signal measurement |
Accuracy |
| Thermocouples (GOST, IEC, DIN) |
±0.1 °C (0°C) (type K) ±0.2 °C (1372°C) (type K) |
| RTDs |
±0.029°C (0°C) ±0.052°C (800°C) (Pt100) |
| System accuracy with external Pt100 reference sensor |
±0.05°C (0°C) ±0.08°C (650°C) |
| Current (4
20 mA) |
±(0.01%RDG+0.01%FS) |
| Voltage (0
12 V) |
±(0.005%RDG+0.01%FS) |
Extra temperature curves, complying with GOST standards
Thermocouples: "PR"(B), "PP"(S, R), "KhA"(K), "KhK"(E,L), "MK"(T), "ZhK"(J), "NN"(N)
RTDs: 50/100/500/1000"P"(Pt), 50/100"M"(Cu), 100"N"(Ni), 23(Cu)
|
|
|