Oxygen content in flue gases is the primary value that is used optimization of combustion processes in different facilities.
Major problems of reliable measurement of oxygen in flue gases are solved successfully by means of zirconium oxide based sensor *.
|
|
In addition to this sensor a catalytic detectors can be installed into the instrument to measure combustibles and/or methane as well.
We offer reliable analyzers capable of operation in wet dirty gases. All analyzers use probes and operate - as a rule - without sample handling systems.
|
|
* For power industry we offer non-explosion proof CEM LAND analyzers
|
WDG-Insitu/210/2000/IQ
 |
Direct insertion type oxygen in flue gas analyzers with separate controllers (except for IQ model) with built-in display, current outputs, contact closures and serial interface.
Operate without sample handling system
| Range |
0.1...100 %O2 |
| Accuracy |
±0.1% O2 or ±3% of reading,
whichever is greater |
| Gas temperature |
20...677°C |
|
1ExdIICT3 X or 2ExpzIICT3 X Ex proof version available
|
|
WDG-IV/C/M/CM/IQ
 |
Close-coupled oxygen and combustibles in flue gas analyzers with fast response.
Design includes probes, field units with detectors and separate controllers (except for IQ model) with built-in display, current outputs, contact closures and serial interface.
Operate without sample handling system
| Ranges |
Accuracies |
| 0...100%O2 |
±0.1% O2 or ±2% of reading, whichever is greater |
| 0...5% combustibles |
±5% of full scale |
| 0...5% methane |
±5% of reading |
|
| Gas temperature |
704°C ... 1760°C |
|
2ExpzIICT3 X Ex proof version available
|
|
WDG-HPII/C/M/CM/IQ
 |
Oxygen and combustibles analyzers to be used in flue gases featuring high particulate levels.
Design includes probes, field units with detectors and separate controllers (except for IQ model) with built-in display, current outputs, contact closures and serial interface.
Operate without sample handling system
| Ranges |
Accuracies |
| 0.1...100%O2 |
±0.1% O2 or ±2% of reading,
whichever is greater |
| 0...1/5% combustibles |
±5% of full scale |
| 0...5% methane |
±5% of reading |
|
| Gas temperature |
704°C ... 1760°C |
|
2ExpzIICT3 X Ex proof version available
|
|
CG1000/CG1100
| |
|
 |
Portable (CG1000) and on-line (TM2000) oxygen analyzers in clean gases.
| Range |
0.1 ppmv...100% O2 |
| Accuracy |
±0.02% O2 or ±2% of reading, whichever is greater |
|
|
|